LAB
ASII-36X36
5년
주장비
시험
기계가공·시험장비 > 재료물성시험장비 > 진동내구시험장비
2016.03.07.
₩224,250,000
기관의뢰
고정형
건별
₩500,000
1. System
a. Type of shock test system
1) Drop type: Free fall
2) A multiple post guidance system with balanced hydraulic lift cylinders provides automatic chatter free positioning and alignment of the shock table.
3) An automated shock drop calculator simplifies the determination of drop heights and pressures to quickly achieve the operator’s requested shock pulses.
4) Fully automated computer controlled shock and data analysis test system.
5) Windows based PC control system with the remote control interface automates procedures and reduces test times.
6) The lowest position of the table should be less than 1.2m.
7) Dual waveform programmers should be installed into the seismic base for low profile and safety.
8) Nitrogen gas should be used for Squarewave test and braking system.
9) The system should be installed on normal laboratory floor without additional construction and extra cost.
b. Table
1) Size: 900 x 900 mm or more
2) Material: Aluminum or magnesium
3) M10 x 1.5 Mounting holes on 100mm centers
c. Maximum acceleration: 600g or more
d. Max. Pulse duration: 65ms or more
e. Min. Pulse duration: 2.0ms or less
f. Max. Free fall velocity change : 7.0m/s or more
g. Max. Accelerated fall velocity change : 11.6m/s or more
h. Seismic base weight: 2,300kg or more
i. Maximum specimen weight: 600kg or more
j Machine height: 3,000mm or less
k Pulse combinations with elastomer half sine performance kit
1) Acceleration(G) : 10 ~ 300
2) Duration(ms) : 2.5 ~ 40
l. Utility
1) HPS: 220V, 3PH, 60Hz
2) Controller: 220V, 1PH, 60Hz
3) Air: 80PSI or others
2. Data Acquisition and analysis System
a. Window based 4-channel or more. Possible to extend up to 16channel
b. Communication: USB interface
c. Built in programmable amplifier or ICP constant flow signal conditioning
d. Resolution for analog to digital conversion: 24 bit or more
e. Manual or automatic triggering modes
f. Automatic analysis of Acceleration, Time, Velocity change, SRS, SR, Tolerance Band
g. Detects Half-Sine, Square, Trapezoidal, and Sawtooth wave forms
h. Independent analog anti-aliasing filtering for each channel and 160dB/OCT digital filtering
i. Shock Resonance Spectrum (SRS) analysis software module
1) Resolution: 1, 1/2, 1/3, 1/6, 1/12, 1/24th multiple frequency formular analysis
2) SRS Chart, SRS Cascade observation, Force deformation analyst, Triaxial analyst and Torsion impact analyst.
j. Damage Boundary Curve (DBC) software module
k. Fast Fourier Transform (FFT) analysis
3. Accessories
a. Accelerometer: Low profile triaxial 1000g ICP accelerometer with 6m cable
b. Elastomer half sine kit for 2.5 ~40ms or more
c. Number of Elastomer kit : 2 kits (refer to III, 1, k) or more
d. Long duration programmer : 65ms or more
1. 본체(Main body): Shock Test System -- 1set
2. Data Acquisition and Analysis System -- 1set
3. Accessories
- Elastomer Half Sine Kit for 2.5 ~40ms or more(2kit)
- Accelerometer: Low profile triaxial 1000g ICP accelerometer
- Long duration programmer : 65ms or more