EM TEST
UCS 200N50/LD 200N/VDS 200N50/CDN 10615N100/PFS 200N50/WAVE GENERATOR(모델명 미입력) 외
9년
주장비
시험
전기·전자장비 > 측정시험장비 > 전자파측정시험장비
2022-10-28
294,000,000원
기관의뢰
이동형
시간별
[Hr] 100,000원
- 전기차 안전편의부품에 대한 과도전압내성 측정장비
- 전기자동차 및 내연기관자동차에서 발생하는 과도전압에 대한 내성 측정장비
- 전장부품에 대한 과도전압내성평가장비
- 부산지역 전장부품업체 기업지원장비
1. Micropulse Generator : 1 SET
1.1. Built-in coupling networks
(1) DUT voltage : Max. 70V or more
(2) DUT current : 100A or more
(3) Peak Current : 150A for 200ms or more
1.2. Electrical Fast Transient
(1) Test Voltage : 30V ~ 1,000V ± 10% or more
(2) Rise time : 5ns ± 1.5ns
(3) Pulse duration : 150ns ±45ns or 100ns ±10%
1.3. Pulse 1
(1) Test Voltage : 20V ~ 330V or more
(2) Rise time : 1μs and 3μs or more
(3) Pulse duration : 2ms, 6ms or more
(4) Internal resistor : 4, 10, 20, 30, 50, 90 ohm or more
1.4. Pulse 2
(1) Test Voltage : 20V ~ 330V or more
(2) Rise time : 1μs or more
(3) Pulse duration : 50μs or more
(4) Internal resistor : 2, 4, 10, 20, 50, 90 ohm or more
1.5. Should generate JASO D-001 pulse A2, B2, D2 and NISSAN 28400 NDS 03,
Pulse B2, NISSAN 28400 NDS 07, pulse C8, C50, C300
2. Load Dump Simulator : 1 SET
2.1. Freestyle mode
(1) Test Voltage (O.C) : 20V ~ 200V ± 10% or more
(2) Rise time : 0.09 ~ 10ms or more
(3) Pulse duration : 30ms ~ 1,200ms or more
(4) Internal resistor : 0.5 ohm ~ 10ohm or more
2.2. Clipped load dump
(1) Clipped voltage : 15 V ~ 95.5 V or more
3. Battery simulator : 1 SET
3.1. Output voltage : -15 V ~ + 70V or wider
3.2. Output current : 0A ~ 100A, Continuous or more
3.3. Peak current : 300A for 200ms or more
3.4. Frequency range : DC to 150kHz or wider
3.5. Source impedance : < 10mohm
3.6. Should generate ISO 7637-2 Pulse 2b and Pulse 4 / LV 148 over voltage and
superimposed AC voltage
4. Waveform generator : 1 SET
4.1. Output channels : 2 CH or more
4.2. Output voltage : -10 ~ +10V
4.3. Frequency : DC - 50kHz or more
4.4. Segment types : DC voltage, Sine, Square, triangle, ramp, exponential wave
4.5. Remote interface : GPIB or more
5. Power fail simulator : 1 SET
5.1. Power line switch
(1) Switch : Switch in the circuit
(2) EUT voltage : ±70V DC or wider
(3) EUT current : 200 mA ~ 100A or wider
(4) Switching time : < 200ns (rise/fall time)
(5) Should be able to perform GMW 3172 9.2.18 switched battery lines
5.2. Signal/Data line switch
(1) Channels : 4 lines or more
(2) EUT voltage : ± 30V DC or bigger
(3) EUT current : 100 μA ~ 2A
(4) Switching time : < 5 μs (rise/fall time)
6. ISO 7637-3 ICC Method kit : 1 SET
6.1. Inductive coupling clamp
6.2. Injection probe with a calibration fixture
6.3. Matching adapter
7. System software : 1 copy
7.1. Should control all the functions of the system
7.2. Should have libraries for international and manufacturer standards