SUGA
GS-UVS
주장비
시험
기타 > >
2011-08-03
325,230,234원
고정형
원
○ 주요사양
1. Performance
1-1. Condition of gas concentration
1) Manual control :
SO2:0.01~ 200 ppm (Volume ratio)
H2S:0.01~ 200 ppm (Volume ratio)
NO2:0.2~ 20 ppm
Cl2:0.01~ 0.02 ppm
2) Automatic control :
SO2:1~ 200 ppm (Volume ratio)
H2S:1~ 200 ppm (Volume ratio)
1-2. Test conditions
1) Temperature : 23℃ ~ 50℃±1℃
2) Humidity control : 50 ~95%RH±3%RH at 23℃~ 50℃
1-3. Test kinds
1) Gas test
2) Air purge test
3) Cyclic test
1-4. Accuracy and distribution of temperature and humidity at specimens area
1) Accuracy : ±1℃, ±3%RH
2) Distribution : ±2℃, ±7%RH
1-5. Dimension and weight
1) Internal size : 500(W) x 500(D) x 600(H) mm
2) External size : 1660(W) x 1310(D) x 1780(H) mm , 400 Kg in approx.
1-6. Specimen
1) Standard size : 150 x 70 x 1(t) mm in approx.
2) Number : 20 pieces at the same time of vertical and 15°
1-7. Sealing method for lid : Double packing sealing method
1-8. Water requirement
1) Pressure : 0.1 ~ 0.2 MPa
2) Amount : 0.3 Liter/h
1-9. Electrical requirement : Three phase 220V/60Hz, 22A , Electrical breaker for Three phase 220V 30A is equipped.
2. Construction
2-1. Main body
Consisting of : Testing chamber is designed with double wall system so as to minimize the fluctuation of temperature.
1) Test chamber : Titanium made
2) Outer parts : Rigid PVC sheet
The constant and uniform temperature is controlled by means of temperature control system which is filling with specially designed materials and double structure.
3) Agitating fan : Acrylic made
4) Specimen rack : Acrylic made with stationary type
5) Gas detection port
6) Base : Stainless made
2-2. Control panel
1) TM-3 cycle computer
- Test kind : Selection and combination are arbitrary
- Testing hour mete