한국애질런트테크놀로지스
5975C inert XL MSD
9년
주장비
분석
화합물 전처리·분석장비 > 질량분석장비 > 기체크로마토그래피질량분석기
2011-12-27
83,000,000원
기관의뢰
고정형
건별
50,000원
전처리가 끝난 시료를 주입부터 장착하고, 헬륨가스를 흘려주어 분석
A. Feature
1. The modular mass analyzer incorporates a solid inert ion source, a proprietary quartz quarupole analyzer and new higher signal-to-noise ratio Triple-Axis Detector. This powerful combination provides better MS resolution, exceptional spectral integrity and lower limits of detection for the highest confidence in the results. New trace ion detection technology provides even more capabilities at trace level.
2. Comprehensive automation features, faster separations and shorter detection cycle times enable you to process more samples in less time. Advanced analysis routines let you get maximum information from every run, and new automated spectral deconvolution software enables rapid identification and quantification.
3. Proprietary inert source in now programmable up to 350℃ to provide enhanced response for active compounds and late-eluters. it delivers improved peak symmetry, higher EI response, fewer degradation ions and more reliable library searches. Higher temperature also means less frequent cleaning a nice improvement for lab's productivity.
4. The detector uses a new ion guide and shield to position a new long-life triple channel electron multiplier(EM) doubly off-axis from the analyzer exit. The optimized ion path increases signal and eliminates noise from energetic neutrals. The result is simply the best signal-to-noise specification in the market, and the perfect complement to the inert source and patented hyperbolic analyzer.
5. Synchronous SIM/Scan functionality lets you capture SIM data and full scan data in the same acquisition. Because of the ease of setup and availability of spectral libraries, many labs use full scan for most of their data collection. SIM mode, on the other hand, offers a significant improvement in sensitivity over full scan data; however, SIM data cannot be searched against commercially available spectral libraries for match confirmation. But, this MSD's synchronous SIM/Scan operation, you can get both in a single run. The AutoSIM software capability automatically converts full scan data into SIM or SIM/Scan acquisition parameters for use in
synchronous SIM/Scan methods. SIM dwell times can be set in 1msec increments from as fast as 1msec to over 100msec dwell time.
6. An intuitive user interface and a CI flow control module work together to automatically adjust the CI reagent gas flow for optimum performance. The dual reagent inlets allow easy comparison of complementary reagents like methane and ammonia.
7. Faster oven cool down, robust backflush capability, advanced automation features and faster
GC/MS oven ramps let you get more done in less time, at the lowest possible cost per sample—all easily incorporated into your existing methods.
8. For non-target compounds, a sensitive, selective GC detector is a powerful complement to MS. That small, unexpected peak on the ECD baseline might provide the only clue to a critical
compound. The GC/MSD Productivity ChemStation will simultaneously acquire signals from two
GC detectors and MSD SIM/Scan signals.
주입부, 컬럼, 오븐, MS검출기
- Mass Analyzer: Quadrupole
- Mass Range:1,050amu
- Scan Rate: 12,500 u/s
- EI scan: 400:1
- EI SIM: 10:1
- PCI scan: 125:1
- PCI SIM: 10:1
- NCI Scan: 600:1
- NCI SIM: 10:1
- Ionization energy : 10~241.5 eV
- Mass filter: Au Q-pole
- Library S/W : NIST, Wiley, Pesticide, Drug